COMPARISON OF DESIGN AND ANALYSIS OF TUBE SHEET THICKNESS BY USING UHX CODE OF ASME AND TEMA STANDARD
In: http://www.iaeme.com/MasterAdmin/UploadFolder/COMPARISON%20OF%20DESIGN%20AND%20ANALYSIS%20OF%20TUBE%20SHEET%20THICKNESS%20BY%20USING%20UHX%20CODE-2/COMPARISON%20OF%20DESIGN%20AND%20ANALYSIS%20OF%20TUBE%20SHEET%20THICKNESS%20BY%20USING%20UHX%20CODE-2.pdf
Online
academicJournal
Zugriff:
In order to investigate the optimized tube sheet thickness different methodologies are used. For the mechanical design of existing fixed tube sheet heat exchanger of a waste heat Boiler various code solutions are compared with each other. Solutions of Finite Element Analysis are used to optimize the design parameters. The purpose of this paper is to compare and analyse tube sheet design code UHX of ASME section VIII Div. 1 with TEMA standards. From the design methodology it is found that both standards are based on different theory of design. It is also found that FE analysis results are closed to exact solution and these results can be accepted with a reasonable degree of accuracy. Thus FEA can be used as an optimization tool for tube sheet thickness.
Titel: |
COMPARISON OF DESIGN AND ANALYSIS OF TUBE SHEET THICKNESS BY USING UHX CODE OF ASME AND TEMA STANDARD
|
---|---|
Autor/in / Beteiligte Person: | Dr Kalpesh D Shirode¹ ; S B Rane² ; Mr Yashwant Naik³ ; The Pennsylvania State University CiteSeerX Archives |
Link: | |
Zeitschrift: | http://www.iaeme.com/MasterAdmin/UploadFolder/COMPARISON%20OF%20DESIGN%20AND%20ANALYSIS%20OF%20TUBE%20SHEET%20THICKNESS%20BY%20USING%20UHX%20CODE-2/COMPARISON%20OF%20DESIGN%20AND%20ANALYSIS%20OF%20TUBE%20SHEET%20THICKNESS%20BY%20USING%20UHX%20CODE-2.pdf |
Medientyp: | academicJournal |
Sonstiges: |
|