A Concept for Energy-Efficient High-Rise Buildings in Hanoi and a Calculation Method for Building Energy Efficiency Factor.
In: Procedia Engineering, Jg. 142 (2016-03-01), S. 153-159
academicJournal
Zugriff:
In order to quantitatively assess how energy-efficient a building can be with regard to building design, the author would like to propose an energy-efficiency factor in buildings (K hqnl ) and a calculation formula for this factor. The actual thermal building calculations show that 86% of the overall heat transfer in a building comes through windows. Therefore the coefficient K hqnl depends largely on the sun-shading capacity of the windows that can be roughly calculated as energy efficiency factor of the window. The author will also address 6 main architectural characteristics of an energy-efficient building concept in Vietnam. [ABSTRACT FROM AUTHOR]
Copyright of Procedia Engineering is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Titel: |
A Concept for Energy-Efficient High-Rise Buildings in Hanoi and a Calculation Method for Building Energy Efficiency Factor.
|
---|---|
Autor/in / Beteiligte Person: | Ha, Pham Thi Hai |
Zeitschrift: | Procedia Engineering, Jg. 142 (2016-03-01), S. 153-159 |
Veröffentlichung: | 2016 |
Medientyp: | academicJournal |
ISSN: | 1877-7058 (print) |
DOI: | 10.1016/j.proeng.2016.02.026 |
Schlagwort: |
|
Sonstiges: |
|